Step 1. Remove eps 30amp fuse
2. Locate eps relay on right of battery, slowly and CARFULLY cut zip ties and tape to expel as much wire as possible.
3. Snip wires going to plug as close to the plug as possible and strip em.
4. Strip and solder you new relay harness don’t forget shrink tube.
5. Plug in your new relay with dielectric grease tape up your relay and loom. Replace all zip ties and oem loom.
6. Route the loom to your pod.
7. Test.
<OEM wire colour> <Position on Relay>
Red = Hot/live POS. <30>
Small orange = Keyed/switched. <86>
Bown = Ground. <85>
Large orange = Accessorie<EPS> <87>
Hope this helps. Couldn’t figure out how to upload pictures from the iPad